FITS Dark Frame Analyzer
Frame A
Frame B (optional)
Exposure times are normalized to seconds from FITS keyword units; ambiguous units are flagged rather than guessed. Supports uncompressed 2D FITS images with BITPIX 8, 16, 32, -32 or -64. Local background uses a 5×5 same-Bayer-position neighborhood. For mono images, the same estimator is used on parity positions for consistency.
FITS metadata
Full-frame statistics
Spatial standard deviation includes fixed-pattern noise, hot pixels and offset variations. It is not temporal read noise.
Frame A · stretched preview
Frame B · stretched preview
Bright outlier pixels · relative comparison
Each threshold is independently scaled to Frame A = 100% (highlighted line); the axis extends to the largest Frame B ratio, so bar heights are proportional. Bar labels show actual pixel counts; percentage labels show the change in Frame B.
Counts are threshold exceedances, not confirmed persistent hot pixels. A master dark built from repeated exposures is needed to identify persistent defects.
Pixel Deviation Distribution
Percentage of sampled pixels with a positive residual above each threshold, relative to the local same-CFA-position median. Higher curves indicate more bright outlier pixels. This is not a temporal noise measurement.
Show original pixel-value histogram (technical view)
Y axis: % of each frame's sampled pixels per bin, so frames of different size are comparable. A taller, narrower peak means pixels are clustered more tightly, not more noise. Shared ADU axis from median − 4·MAD to the 99.9th percentile; values outside are excluded.
Interpretation
For temporal noise and dark-current measurements, use repeated dark and bias frames at matching gain, offset, exposure and temperature. Different temperatures alone do not isolate dark current from read noise.